TchineseEnglish
Your cart contains 3 items
Top » Catalog » Sensors » Temperature/Humidity » 3130_0 » Relative Humidity Sensor HM1500LF [3130_0]
US$73.75

This humidity sensor can measure the relative humidity in the environment from 10% to 95% RH. Connects to an analog input.

Relative Humidity Sensor HM1500LF






This humidity sensor can measure the relative humidity in the environment from 10% to 95% RH. Connects to an analog input.






The 1130 is a dedicated humidity transducer designed for applications where a reliable and accurate measurement is needed.

Its features:

  • Small size product
  • Product free from Lead, Cr(6+), Cd and Hg
  • Humidity calibrated within ±2% @55%RH
  • Ratiometric to voltage supply
  • Patented solid polymer structure
  • High reliability and long term stability
  • Not affected by water immersion
  • Very low temperature dependence
  • Instantaneous de-saturation after long periods in saturation phase
  • Part could be washed with distilled water


  • Formula
    The Formula to translate SensorValue into Relative Humidity is:
    RH (%) = (SensorValue * 0.1906) - 40.2


    Sensor Properties

    Sensor Type Humidity (Ambient)
    Sensor Output Type Ratiometric


    Humidity Sensor

    Humidity Min 10 %RH
    Humidity Max 95 %RH
    Humidity Resolution 0.4 %RH
    Humidity Error (At 55%RH) ± 2 %RH
    Humidity Error Max ± 5 %RH
    Humidity Response Time Max 10 s


    Electrical Properties

    Supply Voltage Min 4.8 V DC
    Supply Voltage Max 5 V DC
    Current Consumption Max 1.4 mA
    Output Impedance 70 £[


    Physical Properties

    Operating Temperature Min -40 °C
    Operating Temperature Max 60 °C
    Cable Length 240 mm


    The easiest way to connect the sensor is to use a 3002 - Sensor Cable 60cm or a 3004 - Sensor Cable 350cm ; cut the sensor cable to the desired length and solder the load cell wires to the sensor cable as follows:


    3130 - Sensor Sensor Cable Function
    Blue RedSupply Voltage
    White Black Ground
    Yellow White Humidity Output Voltage









    FUNCTIONAL

    Then, connect the load cell to any device with an Analog Input.